Fireman Elevator: Purpose and Features

Table of Content [Hide]

    In modern urban life, high-rise buildings are prevalent, and elevators play an indispensable role in connecting different floors. Among these elevators, there is a special type — the fireman elevator, which serves a crucial role during emergencies, especially in the event of a fire. This article will explore the purpose and features of the fireman elevator, revealing its essential functions and characteristics in simple terms.


    Purpose of a Fireman Elevator


    A fireman elevator, as the name suggests, is specifically designed for use by firefighters during emergencies, particularly fires. Its main purposes can be summarized as follows:


    Rapid Access to Fire Locations


    In high-rise buildings, when a fire breaks out, staircases often become impassable due to smoke and high temperatures. In such cases, the fireman elevator becomes a vital passageway, allowing firefighters to quickly reach the affected floor. This rapid access helps them initiate firefighting and rescue operations, effectively controlling the spread of the fire and minimizing damage.


    Transporting Firefighting Equipment and Rescue Supplies


    Firefighters need to carry substantial firefighting equipment and rescue materials during an emergency. Ordinary elevators often become inoperative during a fire due to power outages. In contrast, the fireman elevator remains functional, allowing the transportation of heavy equipment, such as fire extinguishers and rescue stretchers, providing essential support to firefighting and rescue efforts.


    Features of a Fireman Elevator


    The fireman elevator's design and functionality make it indispensable during emergencies. Below are the key features that enable it to perform effectively during fires and other urgent situations:


    Superior Fire Resistance


    One of the most prominent features of a fireman elevator is its fire-resistant design. First, the elevator shaft, machine room, and associated areas are separated into independent fire zones, constructed with fire-resistant materials. Additionally, there are no fire sprinklers installed within the elevator shaft or machine room. The elevator is designed to maintain its structural integrity even at high temperatures, preventing the spread of fire. Fire-resistant doors and other fire protection facilities ensure that smoke and flames are effectively isolated during a fire. Furthermore, the elevator's interior materials must be non-combustible to prevent fire from spreading through the interior finishes.


    Water Resistance


    The electrical equipment within a fireman elevator must have robust water protection to ensure it remains operational during a fire when water flow may be present. Specifically, electrical components within the elevator shaft should be water-resistant, capable of withstanding dripping and spraying water, with an IPX3 rating or higher. Electrical equipment located within 1 meter above the pit floor should have an IP67 rating, ensuring it can withstand significant exposure to water and continue to function reliably during emergencies.


    Backup Power Supply


    During a fire, the building's primary power supply is often interrupted. To ensure the fireman elevator remains operational, it is equipped with a backup power system. When the main power is cut off, the elevator will automatically switch to backup power, allowing it to continue running. This backup system ensures that the elevator is available for firefighting and rescue operations within one minute, providing firefighters with uninterrupted access.


    Emergency Control Features


    The fireman elevator is equipped with emergency control functionality. In the event of a fire, the elevator can follow instructions from the fire control center. During a fire, the elevator enters "Phase 1" by automatically canceling all regular calls and returning to the firefighter entrance floor with its doors open. In "Phase 2", firefighters can use the elevator to navigate floors by pressing the buttons to control door operations and selecting floors. This system prevents civilians from using the elevator during a fire, thereby reducing the risk of danger while ensuring that the elevator remains available for firefighters.


    Emergency Evacuation Design


    If the elevator's door mechanism fails to open during an emergency, the fireman elevator is equipped with an emergency evacuation exit. This exit is typically located at the top of the elevator car and is marked with appropriate signage. In an emergency, firefighters or trapped individuals can use this exit to evacuate, ensuring they have a safe escape route.


    Dedicated Communication Equipment


    To facilitate communication between firefighters and external parties during firefighting and rescue operations, the fireman elevator is equipped with a two-way communication system. This system directly connects the elevator to the firefighter entrance floor and the machine room, enabling voice communication without the need to press buttons. These communication devices are linked to the fire control center and other emergency response departments, ensuring timely transmission of information and distress signals during critical moments.


    Capacity and Size Requirements


    To meet the operational needs of firefighters during firefighting and rescue operations, fireman elevator has larger capacities and cabin sizes compared to regular elevators. Generally, the elevator's load capacity should not be less than 800 kg, with the cabin width at least 1.1 meters and depth at least 1.4 meters. When used for evacuating stretchers, the load capacity should be no less than 1000 kg. These specifications ensure that firefighters can carry sufficient equipment and materials, while also providing adequate space for the safe evacuation and rescue of injured or trapped individuals.


    Conclusion


    As a critical safety feature in high-rise buildings, the fireman elevator plays an essential role in emergencies. It provides firefighters with fast access to fire locations, transports vital firefighting and rescue equipment, and ensures the safe evacuation of people. The elevator's superior fire resistance, water resistance, backup power system, emergency control features, and communication capabilities ensure that it operates reliably during emergencies. In short, the fireman elevator is designed to function seamlessly in fire and rescue operations, making it an indispensable asset in high-rise buildings.

    Recommended IFE Elevators And Escalators Products
    References
    Latest News & Blogs
    Jul 17-2022
    Work Together With Partners
    Work together with partners. On July 17, the 35th Anniversary Brand Ceremony of 2022 IFE Elevator and the Annual Meeting of Global Partners was held in Chengdu, the "Land of Abundance". F...
    Mar 27-2025
    Factors to Consider When Choosing Single-Family Home Elevators
    In recent years, there has been a notable increase in demand for elevators within single-family homes. Whether constructing a new residence or renovating an existing one, installing an elevator repres...
    Jun 11-2025
    IFE Appointed Strategic Supplier by Wanyang Group
    Recently, the Wanyang Group held its grand Supplier Conference under the theme "Working Together for Mutual Success", bringing together numerous supplier partners. During At this major signi...